Spectrophotometer

Single beam/Double Beam UV Visible Spectrophotometer /Atomic Absorption Spectrophotometer/ High Performance Microplate Reader UV Visible Spectrophotometer for DNA, RNA, protein analysis/ FTIR Spectrometer Price With ATR spectrophotometer

Yatherm Scientific manufacturing, supplying, importing, and exporting a wide range of Spectrophotometers include Double Beam UV-VIS, Single-Beam UV-VIS Spectrophotometers, and Visible Range Spectrophotometers. We are a leading supplier of all kinds of a spectrophotometer at a reasonable price in India.

  1. “Yatherm Scientific” provides a wide range of sophisticated, Visible Spectrophotometer that is designed from high-quality raw materials. Our Visible Spectroscopy is in high demand in the global market for high performance and accurate results. Visible Spectrophotometers are very useful instruments for chemical, pharmaceutical, agricultural, biotechnological labs, hospitals, engineering & medical colleges, universities & research institutions.
  1. “Yatherm Scientific” supply a highly advanced and comprehensive range of  UV-VIS Spectrophotometers to suit the customer’s pocket and requirements. The wavelength range is from 190.0 to 1000.0 nm, with a resolution of 0.1 nm is obtained by a microprocessor-controlled stepper motor. A monochromatic using Czerny-Turner mounting technique with 1200 line/mm grating is used. Single Beam UV-VIS Spectrophotometers are widely extremely useful in chemical, pharmaceutical, agricultural, biotechnological labs, hospitals, engineering & medical colleges, universities & research institutions.
  1. “Yatherm Scientific” offers Double Beam UV-VIS Spectrophotometers are highly accurate and easy to operate instruments for spectrophotometric analysis of any concentration. Double Beam UV-VIS Spectrophotometer is an extremely useful chemical, pharmaceutical, agricultural, biotechnological labs, hospitals, engineering & medical colleges, universities & research institutions.

 

Application and Standard:
Category Test items Testing standards
Food coloring agent Nitrates and Nitrite GB/T 5009.33
Food contact materials Sulphur dioxide GB 31604.32
Food bleach Nitrite GB/T 5009.34
Ambient air Sulphur dioxide HJ 483
Pasta food Aluminum GB/T 5009.182
The room needs air Formaldehyde GB 50325
Water Quality Analysis Total nitrogen HJ 636

Product Parameters

Model
YS – UV1000G
YS – V1000G
Optical System
Single beam, grating 1200L/mm
Wavelength
200-1020nm
325-1020nm
Spectral Bandwidth
4nm
Wavelength Accuracy
±1.5nm
Wavelength Repeatability
≤0.2nm
Photometric Accuracy
+0.002Abs (0-0.5Abs), ±0.004A (0.5-1.0Abs), ±0.4%T (0-100%T)
Photometric Repeatability
0.001Abs(0-0.5Abs), 0.002Abs(0.5-1.0Abs), <0.2%T (0-100%T)
Stray Light
≤0.1%T(220nm,360nm)
Stability
±0.001A/h(500nm)
Photometric Range
-0.301-3.0A 0-200%T 0-9999C
Photometric Mode
A T C F
Wavelength Setting
Automatic
Output
RS232 printer data output, USB-B connection
Detector
Imported silicon photodiode
Light Source
Deuterium lamp, tungsten lamp
Tungsten lamp
Standard Accessories
4*glass cuvette, 2*quartz cuvette
4*glass cuvette
Power Supply
100-220V 50/60Hz
External Size
466*384*201mm
Net Weight
11.6kg
Packing Size
590*480*315mm
Gross Weight
14.4kg
14kg
Atomic Absorption Spectrophotometer 

Higher Reliability

  • Yatherm Scientific has rich experience in AAS R&D equipment manufacturing
  • Aberration eliminated C-T type monochromator with stable performance
  • High quality imported modular electronic circuits with user friendly operation and maintenance
  • Gas and liquid separator with gas filter offers the uniqueness to work in highly humid environment.

 

Higher Safety

  • Multiple safety features like interlocking and prompt information display makes this device highly safe.
  • Humanized advance program calculates the lamp current in real time that protects the hollow cathode.
  • Advance and Modular gas supply system has less number of fault rate.
  • Highly accurate mass flow controller with flame controlling system regulates the flow of fuel precisely. Temperature controller save guard the complete air circuit breaker from abnormal rise of temperature.

 

Fewer Faults

  • We use high quality imported PMT as the detector that decreases the chance of fault.
  • Inbuilt system of spraying chamber provides the stability to the system in case of temperature rise and strong acids.
  • Our data transmission technology is reliable as we use bussing technique in communication system.

 

SPECIFICATIONS:

Main Specification

Wavelength range

190-900nm
Wavelength accuracy Better than ±0.20nm
Baseline stability 0.006A/30min

 

Light Source System Lamp turret Motorized 8-lamp turret ( Two high performance HCLs can be mounted on the turret to increase the sensitivity in flame analysis.);
Lamp current adjustment 0~15mA
Optical System Monochromator Single beam, Czerny-Turner design grating monochromator
Grating 1800 l/mm
Focal length 277mm
Blazed Wavelength 250nm
Spectral Bandwidth 0.1nm, 0.2nm, 0.4nm, 0.8nm,1.6nm, auto-switch over
Flame Atomizer Burner 10cm single slot all-titanium burner
Spray chamber Corrosion resistant all-plastic spray chamber
Nebulizer High efficiency glass nebulizer with metal sleeve, sucking up rate:6-7ml/min
Emission burner provided

 

Detection and Data Processing System Detector R928 Photomultiplier with high sensitivity and wide spectral range.
Software Under Windows operating system
Analytical method Working curve auto-fitting; standard addition method; automatic sensitivity correction, automatic calculation of concentration and content.
Repeat times 1-99 times, automatic calculation of mean value, standard deviation and relative standard deviation.
Multi-task Functions Sequential measurement for multi-element determination to the same sample
Condition reading With model function
Result printing Measurement data and final analytical report printout, editing with Excel

Dual Beam UV Spectrophotometer

  • High excellent optical system design with holographic sparkling grating assures that the instrument has lower stray light.
  • Control panel operating software has advance and unique analysis capabilities.
  • Dual beam UV spectrophotometers are designed in eight pool structure.
  • User friendly structure and easy replacement design helps in replacing the accessories for different analysis.
  • Easy to replace light source of the spectrophotometer.
  • Open type light source room design.
  • Low noise with high degree of stability
  • Dual beam measuring system
  • Fully Automatic controlling
  • Main components are of high quality  that ensures the safety and reliability.

Technical Specifications:

Operating mode
host operation or PC operation, including online software, can do stand-alone scanning
Wavelength range
190 – 1100 nm
Wavelength Accuracy
± 0.1 nm (D2 656.1 nm), ± 0.3 nm (full wavelength range)
Wavelength repeatability
≤ 0.1nm
Spectral bandwidth
1nm
Optical system
double beam, CT type optical path; 1200 lines / mm laser holographic diffraction grating
Work mode
T, A, C, E
Photometric range
-4 – 4A; 0-200% T
Photometric accuracy
± 0.002A (0-0.5A), ± 0.004A (0.5-1A), ± 0.2% T (0 ~ 100% T)
Photometric repeatability
± 0.001A (0-0.5A), ± 0.002A (0.5-1A), ± 0.1% T (0 ~ 100% T)
Stray light
≤ 0.02% T
Baseline flatness
± 0.0004A
Stability
 ± 0.0004A (at 500nm)
Photometric noise
± 0.0004A
Data output
320 × 240 LCD graphics display, optional USB 2.0 printer or U disk data output, USB connecting to software
Light source
imported long life tungsten lamp, deuterium lamp
Dimensions
670x 560×260 mm
Weight
24kg

High Performance Microplate Reader / UV Visible micro-plate Spectrophotometer

These UV/VIS spectrophotometers are equipped with wavelength selection method which is a perfect tool for the applications of DNA, RNA & protein analysis. It is fully automatic and works with very less user effort.

  • Linear Shaking Motion
  • 96 Wells plate to 384 Wells plate measurement
  • 7 inches or 10 inches touch panel
  • PC Software analyze, record and validate.
  • USB data port with Wi-Fi system
  • Wavelength selection mode
  • Advance Monochromator System
  • A broad wavelength range with the UV area
  • Pathlength correction with fast spectral scanning

 

Technical Specifications:
Model
NANO 100
NANO 300
NANO 400A
NANO 500
Wavelength Range
200-800nm
200-800nm
260nm, 280nm
200-800nm
Minimum Sample Size
0.5-2.0uL
0.5-2.0uL
1-2.0uL
0.5-2.0uL
Path Length
0.2mm
1.0mm
0.2mm
1.0mm
0.5mm
0.05mm
0.3mm
1.0mm
Light Source
Xenon flash lamp
Xenon flash lamp
UVLED
Xenon flash lamp
Detector Type
3864-Linear CCD array
2048-Linear CCD array
UV-sillion photocell
2048-Linear CCD array
Wavelength Accuracy
1nm
1nm
1nm
Spectral Resolution
≦3nm (FWHM at Hg546 nm)
546nm Hg546 HGHGHHHhGhghhgHg546 Hg546nm)
≧3nm (FWHM at Hg546nm
≦3nm(FWHM at Hg546nm)
Hg546om]
Absorbance Precision
0.003Abs
0.003Abs
0.005Abs
0.003Abs
Absorbance Accuracy
1%(7.332Abs at 260nm)
1% (7.332Abs at 260nm)
1% (7.332Abs at 260nm)
1%(7.332Abs at 260nm)
Absorbance Range
0.02 – 90A
0.02 – 100A
0.02 – 80A
0.02 – 100A
Detects Nucleic Acid up to
2-4500ng/ul (dsDNA)
2-5000ng/ul (dsDNA)
10-4000ng/ul (dsDNA)
2-15000ng/ul (dsDNA)
Measurement Time
<8S
<5S
<8S
<6S
Data Output
Connect PC
USB
USB
USB
Operating Voltage
24V DC
24V DC
24V DC
24V DC
Operating Power
20W
25W
25W
25W
Standby Power
5W
5W
5W
5W
Packing Size (W x D x H)
500 x 495 x 310mm
500 x 495 x 310mm
500 x 495 x 310mm
500 x 495 x 310mm
Gross Weight
9.2kg
9.2kg
9.2kg
9.2kg
Software Compatibility
WinXP, Win7. Win8
Android System
Android System
Android System
Fluorescent detection
Sensitivity
dsDNA: 0.5pg/ul
Linear Dynamic Range
R2>0.995
Repeatability
<1.5%
OD600nm Measurement
Light Source
LED
LED
LED
Wavelength Range
600±8nm
600±8nm
600±8nm
Absorbance Range
0-4A
0-4A
CMA

We manufacture & offer customized and standard instruments for our customers at the best price in India and Worldwide. We give a year warranty for all instruments with ten years of spare parts availability for better customer relationships.

Quotation Request Form

Please enable JavaScript in your browser to complete this form.